Clinically, syringe pump products are usually used for a long period of time to maintain a constant drug delivery rate and precise dosage of arterial and intravenous infusion environment
Clinically, syringe pump products are usually used for a long period of time to maintain a constant drug delivery rate and precise dosage of arterial and intravenous infusion environment, mostly used to inject dopamine, dobutamine, epinephrine, normethyl Adrenaline, lidocaine, nitroglycerin, sodium nitroprusside and other cardiovascular active drugs, narcotics, and hormones that require precise control with a small amount of liquid and high concentrations. Other liquids can also be injected according to clinical needs.
Mainly applicable departments: ICU, CCU, NICU, RICU, EICU, PICU, and other intensive care units are standard configurations; operating rooms, cardiovascular and cerebrovascular departments, and some surgical departments.
Syringe specifications: 5 ml, 10ml, 20ml, 30ml, 50ml
Liquid injection speed unit: the injection speed unit should have 10 units: ml/h, ml/min, mg/h, µg/h, mg/min, µg/min, mg/kg/h, µg/kg/h, mg/kg/min, µg/kg/min
Rapid injection speed (Bolus): 150ml/h (5 ml syringe) 300ml/h (10 ml syringe) 600ml/h (20 ml syringe)900ml/h (30 ml syringe) 1500ml/h (50 ml syringe)
KVO rate: 1ml/h
Blocking pressure: 20 ~ 160KPa, adjustable in 3 levels of high, medium and low
Alarm: self-check, AC power failure, battery undervoltage, pipeline blockage, liquid medicine is almost exhausted, liquid medicine is exhausted, injection is completed, syringe falls off, needle tube is placed incorrectly, etc.
Power supply: AC power supply: AC100-240V 50/60Hz; DC power supply: DC11.1V, rechargeable lithium battery; power supply time: 2 hours
Dimensions: 350×180×240mm
Weight: 5.5kg
Power: 35VA
1. Automatically identify and use 5-50ml syringes, and can be used with any manufacturer's brand syringes.
2. Chinese menu operation, digital keyboard precise input, only three steps to operate the injection pump, start, input speed, start, convenient and quick.
3. Super large color LCD display, intelligent display of multiple parameters on the same screen, dynamic and intuitive.
4. With operation modes such as speed, time, weight, etc., and more than a dozen international units, it is more convenient for clinical application.
5. The claw-type syringe pusher box is designed to meet clinical one-hand aseptic operation.
6. Design the extension tube fixing clip to ensure the safety of injection.
7. Unique liquid crystal display design, backlit viewing is also clear.
8. The injection speed is 0.1~1500, which is more accurate and convenient for clinical use.
9. Unique emergency stop button switch design, clinical use is safer.
10. The integrated design prevents the leakage of the liquid medicine and increases the service life of the machine.