Products+

    Contact us

    Electrosurgical unit7

    It is suitable for ENT and ophthalmology, aesthetic plastic surgery, burn surgery, etc.

    Nine Working Modes

    Mono cut Cutting: 100W (load 500) Mono Coag Soft Coag: 60W (load 500)
    Blend: 80W (load 500)
    Bipolar Bipolar Coag: 50W (load 200)

    Technical Parameters

    Ambient temperature range: 10ºC~40ºC;   Relative humidity range: 30%~75%;
    Atmospheric pressure range: 700hpa~1060hpa; Power supply: 220V (±22V), 50Hz (±1Hz);
    Working frequency: 360kHz~460 kHz; Type of equipment: CF;
    The power consumption of the whole device is less than 1000VA. (Cutting function: 100W)

    Transport and Storage

    • (a)Ambient temperature range: -40ºC~55ºC;
    • (b)Relative humidity range: ≤93%;
    • (c)Atmospheric pressure range: 500hpa~1060hpa;

    Scope of Application

    • It is suitable for ENT and ophthalmology, aesthetic plastic surgery, burn surgery, etc.

    Functional Features

    • 1.Cutting: that is pure cutting, the effect is fine cutting, tissue surface is fresh and no scab;
    • 2.Blend: The effect is to provide good coagulation while cutting. It is suitable for superficial coagulation of tissue in surgery and can be used with endoscopy.
    • 3.Coag: It can be called soft electrocoagulation or point coagulation. It is suitable for deeper coagulation of tissue in surgery and can be used with endoscopy. Because smaller area of action can reduce adhesion between electrode and tissue, it is better for rehabilitation of patients.
    • 4. Bipolar Coag: It can be called rapid bipolar electrocoagulation. It can achieve the effect of coagulation at the moment of start-up and reduce the rate of misoperation during surgery.

    Product Advantages

    • 1.Independent output port of endoscope and intelligent conversion key, which can enter endoscopic mode automatically after start-up.
    • 2.Microcomputer control system, power-off protection, and memory function of keeping last usage data after restart.
    • 3.Automatic adjustment on output power. It can be adjusted automatically according to the change of density of tissue. Stable output power to keep the minimum wastage.
    • 4.Automatic conversion on monopolar and bipolar.
    • 5.Automatic monitoring of on-off, automatic detection and error prompt in work.
    • 6.The monitoring circuit system on contact quality of neutral electrode can test and evaluate the safety and effectiveness on the contact area between electrode plate and skin. The system can cut off output automatically and give an alarm, in case of finding that contact area is in dangerous level. It can test and use negative plate of monopolar or bipolar effectively.
    • 7.Operating panel with keys, high definition and large digital. It has different sound and light indicators during operation. Waterproof operating keys easy to clean and maintain.
    • 8.Independent three-way power output. This increases the convenience and security of operation.
    • 9.It can be operated and performed well underwater even when dissecting and removal of fat tissue.
    • 10.Fully suspended power output. There are two independent and isolated application sections to prevent defibrillation interference (monopolar and bipolar).

    Home Tel Mail Inquiry